Full Text Journal Articles by
Author Safoura Ghodsi

Advertisement

Find full text journal articles








Effect of aging on fracture resistance and torque loss of restorations supported by zirconia and polyetheretherketone abutments: An in vitro study.

Safoura Ghodsi, Michel Tanous, Mohammadreza Hajimahmoudi, Hoseinali Mahgoli,

<h4>Statement of problem</h4>New materials have been developed for digital processing, including implant abutments, but studies on their mechanical properties are lacking.<h4>Purpose</h4>The purpose of this in vitro study was to compare the effect of aging on the fracture resistance, failure mode, and torque loss of restorations made of zirconia and ceramic-reinforced polyetheretherketone ... Read more >>

J Prosthet Dent (The Journal of prosthetic dentistry)
[2020, :]

Cited: 0 times

View full text PDF listing >>



A clinical comparison of digital and conventional impression techniques regarding finish line locations and impression time.

Soudabeh Koulivand, Safoura Ghodsi, Hakimeh Siadat, Marzieh Alikhasi,

<h4>Objective</h4>This study compared digital and conventional impression techniques regarding impression time, frequency of adjustments, and adaptation of cobalt-chromium (Co-Cr) copings with supragingival and subgingival finish lines.<h4>Materials and methods</h4>Thirty premolars prepared for single-unit metal-ceramic restorations with supragingival and subgingival finish lines (n = 15). Conventional impression and digital scan of prepared ... Read more >>

J Esthet Restor Dent (Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.])
[2020, 32(2):236-243]

Cited: 2 times

View full text PDF listing >>



Advertisement

Comparison of Marginal Adaptation of Different Implant-Supported Metal-Free Frameworks Before and After Cementation.

Somayeh Zeighami, Safoura Ghodsi, Majid Sahebi, Samira Yazarloo,

<h4>Purpose</h4>To compare marginal adaptation before and after cementation of implant-supported metal-free frameworks fabricated from zirconia, polyetheretherketone (PEEK), or composite.<h4>Materials and methods</h4>Thirty-six CAD/CAM frameworks were constructed from zirconia, PEEK, or composite (n = 12 per material). Marginal gap was measured using a Video Measuring Machine (VMM) system, and repeated-measures analysis of ... Read more >>

Int J Prosthodont (The International journal of prosthodontics)
[2019, 32(4):361-363]

Cited: 1 time

View full text PDF listing >>



Comparing Retention and Internal Adaptation of Different Implant-Supported, Metal-Free Frameworks.

Safoura Ghodsi, Somayeh Zeighami, Mojdeh Meisami Azad,

<h4>Purpose</h4>This study was conducted to compare the fit and retention of implant-supported, metal-free copings fabricated from zirconia, polyetheretherketone (PEEK), or composite, as well as to evaluate the possible correlation between internal adaptation and retention.<h4>Materials and methods</h4>A total of 36 copings were milled from zirconia, PEEK, or composite blanks (n = ... Read more >>

Int J Prosthodont (The International journal of prosthodontics)
[2018, 31(5):475-477]

Cited: 1 time

View full text PDF listing >>



Comparative Evaluation of Fracture Resistance and Mode of Failure of Zirconia and Titanium Abutments with Different Diameters.

Reza Shabanpour, Niloufar Mousavi, Safoura Ghodsi, Marzieh Alikhasi,

<h4>Aim</h4>The purpose of the current study was to compare the fracture resistance and mode of failure of zirconia and titanium abutments with different diameters.<h4>Materials and methods</h4>Fourteen groups of abutments including prefabricated zirconia, copy-milled zirconia and titanium abutments of an implant system (XiVE, Dentsply) were prepared in different diameters. An increasing ... Read more >>

J Contemp Dent Pract (The journal of contemporary dental practice)
[2015, 16(8):613-618]

Cited: 0 times

View full text PDF listing >>



Implant Rehabilitation in Advanced Generalized Aggressive Periodontitis: A Case Report and Literature Review.

Sasan Rasaeipour, Hakimeh Siadat, Amiralireza Rasouli, Neda Sajedinejadd, Safoura Ghodsi,

Dental implants have provided exceptional rehabilitative options for edentulous and partially edentulous patients. However, as more implants come into play, the more the clinicians come across problems where specific considerations must be taken into account to meet expectations. The Toronto Bridge is a treatment modality proposed for restoring several teeth ... Read more >>

J Dent (Tehran) (Journal of dentistry (Tehran, Iran))
[2015, 12(8):614-620]

Cited: 0 times

View full text PDF listing >>



Practical guidelines for fabricating mandibular guide flange prostheses: A new technique for measuring the flange angulation.

Farideh Geramipanah, Saman Fallahi Sichani, Susan Mirmohammadrezaei, Safoura Ghodsi,

<h4>Background and aim</h4>When a mandibulectomy causes discontinuity, the patient will need a rehabilitative prosthesis to achieve a proper occlusal relationship.<h4>Technique</h4>This article describes step-by-step guidelines for measuring the patient-specific mandibular guide flange angulation. In the presented technique, the flange angulation is determined by dividing the horizontal overlap of the maxillary posterior ... Read more >>

Prosthet Orthot Int (Prosthetics and orthotics international)
[2016, 40(4):528-531]

Cited: 0 times

View full text PDF listing >>



A clinical comparative study of Cadiax Compact II and intraoral records using wax and addition silicone.

Kianoosh Torabi, Sasan Rasaei Pour, Ahmad Hassan Ahangari, Safoura Ghodsi,

Evaluation of mandibular movements is necessary to form the occlusal anatomical contour, analyze the temporomandibular joint status, and evaluate the patient's occlusion. This clinical study was conducted to compare the mandibular recording device Cadiax Compact II with routine intraoral records for measuring condylar inclinations. The results showed that the differences ... Read more >>

Int J Prosthodont (The International journal of prosthodontics)
[2014, 27(6):541-543]

Cited: 1 time

View full text PDF listing >>



Evaluation of the effect of a home bleaching agent on surface characteristics of indirect esthetic restorative materials--part II microhardness.

Kianoosh Torabi, Sasan Rasaeipour, Safoura Ghodsi, Amir Ali Reza Khaledi, Mahroo Vojdani,

<h4>Background</h4>The exponential usage of esthetic restorative materials is beholden to society needs and desires. Interaction between the bleaching agents and the esthetic restorative materials is of critical importance.<h4>Aim</h4>This in vitro study has been conducted to evaluate the effect of a home bleaching agent, carbamide peroxide (CP) 38%, on the microhardness ... Read more >>

J Contemp Dent Pract (The journal of contemporary dental practice)
[2014, 15(4):438-443]

Cited: 1 time

View full text PDF listing >>



Evaluation of the effect of a home-bleaching agent on the surface characteristics of indirect esthetic restorative materials: part I--roughness.

Kianoosh Torabi, Sasan Rasaeipour, Amir Alireza Khaledi, Mahroo Vojdani, Safoura Ghodsi,

<h4>Background</h4>Pressing esthetic demands of good looking make people undergo bleaching procedures. However, the effect of bleaching agents on esthetic restorative materials with different surface preparations has been poorly studied.<h4>Aim</h4>The aim of this study was to examine the effect of a homebleaching agent (carbamide peroxide: CP 38%) on the surface roughness ... Read more >>

J Contemp Dent Pract (The journal of contemporary dental practice)
[2014, 15(3):326-330]

Cited: 0 times

View full text PDF listing >>



Evaluation of the Cadiax Compact® II accuracy in recording preadjusted condylar inclinations on fully adjustable articulator.

Ahmad Hasan Ahangari, Kianoosh Torabi, Sasan Rasaei Pour, Safoura Ghodsi,

<h4>Background</h4>Mandibular movement analysis is a critical step in making the functional occlusal morphology and improving the diagnosis and treatment of temporomandibular joint disorders (TMDs). Cadiax Compact® is an electronic condylograph that claims to record the horizontal condylar inclination (HCI), Bennett angle (BA) and relative shape of the articular eminence. This ... Read more >>

J Contemp Dent Pract (The journal of contemporary dental practice)
[2012, 13(4):504-508]

Cited: 2 times

View full text PDF listing >>





Advertisement

Disclaimer
0.7882 s