Full Text Journal Articles by
Author Farideh Geramipanah

Advertisement

Find full text journal articles








Management of Limited Interocclusal Distance with the Aid of a Modified Surgical Guide: A Clinical Report.

Farideh Geramipanah, Leyla Sadighpour, Amirreza Hendi,

In completely edentulous patients, limited interarch distance can compromise conventional prosthetic fabrication. Bone reduction through various surgical procedures has been recommended to restore an acceptable interarch distance. In such circumstances, a surgical guide built on a mounted cast can be used to minimize and control the amount of bone reduction ... Read more >>

J Dent (Tehran) (Journal of dentistry (Tehran, Iran))
[2017, 14(2):105-108]

Cited: 0 times

View full text PDF listing >>



Comparison of Flexural Strength of Resin Cements After Storing in Different Media and Bleaching Agents.

Farideh Geramipanah, Susan Mir Mohammad Rezaei, Maryam Jafary, Leyla Sadighpour,

The aim of this study was to determine the effects of different storage media and bleaching treatments on the flexural strength of two resin cements (Panavia and BisCem). One hundred rectangular-shaped specimens were prepared with two resin cements and were stored in five media types (n = 10): distilled water ... Read more >>

Eur J Prosthodont Restor Dent (The European journal of prosthodontics and restorative dentistry)
[2015, 23(2):56-61]

Cited: 1 time

View full text PDF listing >>



Advertisement

Dynamic nature of abutment screw retightening: finite element study of the effect of retightening on the settling effect.

Haddad Arabi Bulaqi, Mahmoud Mousavi Mashhadi, Hamed Safari, Mohammad Mahdi Samandari, Farideh Geramipanah,

<h4>Statement of problem</h4>A fundamental problem in fully understanding the dynamic nature of screw loosening is lack of recognition of the entire process of screw tightening and retightening.<h4>Purpose</h4>The purpose of this study was to explain the dynamic nature of abutment screw retightening by using finite element methods to investigate the effect ... Read more >>

J Prosthet Dent (The Journal of prosthetic dentistry)
[2015, 113(5):412-419]

Cited: 9 times

View full text PDF listing >>



Practical guidelines for fabricating mandibular guide flange prostheses: A new technique for measuring the flange angulation.

Farideh Geramipanah, Saman Fallahi Sichani, Susan Mirmohammadrezaei, Safoura Ghodsi,

<h4>Background and aim</h4>When a mandibulectomy causes discontinuity, the patient will need a rehabilitative prosthesis to achieve a proper occlusal relationship.<h4>Technique</h4>This article describes step-by-step guidelines for measuring the patient-specific mandibular guide flange angulation. In the presented technique, the flange angulation is determined by dividing the horizontal overlap of the maxillary posterior ... Read more >>

Prosthet Orthot Int (Prosthetics and orthotics international)
[2016, 40(4):528-531]

Cited: 0 times

View full text PDF listing >>



Effect of the coefficient of friction and tightening speed on the preload induced at the dental implant complex with the finite element method.

Haddad Arabi Bulaqi, Mahmoud Mousavi Mashhadi, Farideh Geramipanah, Hamed Safari, Mojgan Paknejad,

<h4>Statement of problem</h4>To prevent screw loosening, a clear understanding of the factors influencing secure preload is necessary.<h4>Purpose</h4>The purpose of this study was to investigate the effect of coefficient of friction and tightening speed on screw tightening based on energy distribution method with exact geometric modeling and finite element analysis.<h4>Material and ... Read more >>

J Prosthet Dent (The Journal of prosthetic dentistry)
[2015, 113(5):405-411]

Cited: 5 times

View full text PDF listing >>



Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: A finite element analysis.

Haddad Arabi Bulaqi, Mahmoud Mousavi Mashhadi, Hamed Safari, Mohammad Mahdi Samandari, Farideh Geramipanah,

<h4>Statement of problem</h4>Implants in posterior regions of the jaw require short dental implants with long crown heights, leading to increased crown-to-implant ratios and mechanical stress. This can lead to fracture and screw loosening.<h4>Purpose</h4>The purpose of this study was to investigate the dynamic nature and behavior of prosthetic components and preimplant ... Read more >>

J Prosthet Dent (The Journal of prosthetic dentistry)
[2015, 113(6):548-557]

Cited: 12 times

View full text PDF listing >>



Effects of impression levels and trays on the accuracy of impressions taken from angulated implants.

Farideh Geramipanah, Majid Sahebi, Maryam Davari, Mohammadreza Hajimahmoudi, Vahid Rakhshan,

<h4>Background and purpose</h4>It is crucial to keep the misfit of the abutment-fixture unit at the lowest possible rate. There are a few controversial studies on the accuracy of impression making of angulated implants, and much fewer (and controversial) studies on the abutment-level impression technique, which is a convenient and clinically ... Read more >>

Clin Oral Implants Res (Clinical oral implants research)
[2015, 26(9):1098-1105]

Cited: 7 times

View full text PDF listing >>



The effect of thermocycling on tensile bond strength of two soft liners.

Farideh Geramipanah, Masoumeh Ghandari, Somayeh Zeighami,

<h4>Objective</h4>Failure of soft liners depends mostly on separation from the denture base resin; therefore measurement of the bond strength is very important. The purpose of this study was to compare the tensile bond strength of two soft liners (Acropars, Molloplast-B) to denture base resin before and after thermocycling.<h4>Materials and methods</h4>Twenty ... Read more >>

J Dent (Tehran) (Journal of dentistry (Tehran, Iran))
[2013, 10(5):405-410]

Cited: 1 time

View full text PDF listing >>



Verification of the mechanostat theory in mandible remodeling after tooth extraction: animal study and numerical modeling.

Ali Mahnama, Mohammad Tafazzoli-Shadpour, Farideh Geramipanah, Mohammad Mehdi Dehghan,

Bone tissue is capable of remodeling in response to environmental and physiological conditions. Mechanical loading is thought to be one of the most important environmental factors, affecting bone status. Mechanostat theory, which classifies bone behavior on the basis of the mechanical strain, has been vastly applied in cases of long ... Read more >>

J Mech Behav Biomed Mater (Journal of the mechanical behavior of biomedical materials)
[2013, 20:354-362]

Cited: 5 times

View full text PDF listing >>



Active tactile sensibility of single-tooth implants versus natural dentition: a split-mouth double-blind randomized clinical trial.

Mahmoud Kazemi, Farideh Geramipanah, Ramin Negahdari, Vahid Rakhshan,

<h4>Background</h4>Unlike passive sensitivity of implants/teeth that is assessed more, only three controversial studies have compared active tactile sensibility (ATS) of implants and teeth.<h4>Purpose</h4>We aimed to explore the difference between the ATS of teeth and single-tooth implants.<h4>Methods</h4>The ATS of single-tooth implants and contralateral teeth was measured in 25 patients after they ... Read more >>

Clin Implant Dent Relat Res (Clinical implant dentistry and related research)
[2014, 16(6):947-955]

Cited: 7 times

View full text PDF listing >>



Using neutral zone concept in prosthodontic treatment of a patient with brain surgery: a clinical report.

Leyla Sadighpour, Farideh Geramipanah, Saman Falahi, Maryam Memarian,

The prosthodontic treatment of a patient who had undergone brain surgery to resect a brain stem astrocytoma has been described. Since the motor innervation to the oral muscles was impaired, the new neutral zone was recorded by using a tissue conditioner material. The teeth and polished surfaces of the mandibular ... Read more >>

J Prosthodont Res (Journal of prosthodontic research)
[2011, 55(2):117-120]

Cited: 2 times

View full text PDF listing >>



Estimation of the safe distance between the implant and an adjacent tilted implant using trigonometry.

Farideh Geramipanah, Leyla Sadighpour,

J Oral Implantol (The Journal of oral implantology)
[2012, 38(3):289-290]

Cited: 0 times

View full text PDF listing >>



Fixed rehabilitation of an ACP PDI class III patient with amelogenesis imperfecta.

Leyla Sadighpour, Farideh Geramipanah, Sakineh Nikzad,

This clinical report describes the oral rehabilitation of a 19-year-old woman diagnosed with hypoplastic-type amelogenesis imperfecta (AI). She presented with discolored and mutilated teeth, missing teeth, anterior open bite, and posterior short crowns. She was classified as an American College of Prosthodontists Prosthodontic Diagnostic Index (ACP PDI) class III patient. ... Read more >>

J Prosthodont (Journal of prosthodontics : official journal of the American College of Prosthodontists)
[2009, 18(1):64-70]

Cited: 6 times

View full text PDF listing >>



Prosthodontic Rehabilitation of a Bruxer Patient with Severely Worn Dentition: A Clinical Case Report

Farhang Mahboub, Elnaz Moslehi Fard, Farideh Geramipanah, Habib Hajimiragha,

The management of tooth wear has been a subject of increasing interest from both preventive and restorative points of view. This article describes the full mouth rehabilitation of a 54-year-old bruxer woman with a severely worn dentition and other dental problems including unsuitable restorations and several missing teeth. The treatment ... Read more >>

J Dent Res Dent Clin Dent Prospects (Journal of dental research, dental clinics, dental prospects)
[2009, 3(1):28-31]

Cited: 0 times

View full text PDF listing >>



Prosthodontic rehabilitation of a bruxer patient with severely worn dentition: a clinical case report.

Farhang Mahboub, Elnaz Moslehi Fard, Farideh Geramipanah, Habib Hajimiragha,

The management of tooth wear has been a subject of increasing interest from both preventive and restorative points of view. This article describes the full mouth rehabilitation of a 54-year-old bruxer woman with a severely worn dentition and other dental problems including unsuitable restorations and several missing teeth. The treatment ... Read more >>

J Dent Res Dent Clin Dent Prospects (Journal of dental research, dental clinics, dental prospects)
[2009, 3(1):28-31]

Cited: 2 times

View full text PDF listing >>



Patient satisfaction with implant-retained mandibular overdentures: a retrospective study.

Hakimeh Siadat, Marzieh Alikhasi, Ali Mirfazaelian, Farideh Geramipanah, Farid Zaery,

<h4>Purpose</h4>The aim of this study was evaluation of the effect of age, gender, and past prosthetic history (duration of edentulism, number of complete dentures before implant treatment, and number of adjustment appointments) on patients' ratings of satisfaction (comfort, hygiene, retention, appearance, speech, mastication, and overall satisfaction).<h4>Materials and methods</h4>In this retrospective ... Read more >>

Clin Implant Dent Relat Res (Clinical implant dentistry and related research)
[2008, 10(2):93-98]

Cited: 20 times

View full text PDF listing >>





Advertisement

Disclaimer
0.9646 s